Expansion joint covers for non-completed floors in areas with very high load capacity requirements. Product type F-HD 40 can be installed on completed floors when an extra groove is formed on the joint (2nd drawing.)
F-HD
Expansion joint covers for non-completed floors in areas with very high
load capacity requirements.
Use:
Material:
Mill finish or clear-anodized aluminium alloy 60.63-T5 with non-skid
striated visible surface.
Load Capacity:
Heavy duty traffic. Very high load capacity assembly suitable for installation in areas with forkliſt trucks (with solid or pneumatic tires) and trucks such as storage areas, manufacturing units and logistics warehouses etc.
Load capacity test results for F-HD 40: For uniform load: 174kN
(Complete test report from independent laboratory available upon request.
Test reports for other sizes available upon request).
Use:
Expansion joint covers for non-completed floors in areas with very high load capacity requirements. Product type F-HD 40 can be installed on completed floors when an extra groove is formed on the joint (2nd drawing.)
Material:
Mill finish or clear-anodized aluminium alloy 60.63-T5 with non-skid
striated visible surface.
Load Capacity:
Heavy duty traffic. Very high load capacity assembly suitable for installation in areas with forkliſt trucks (with solid or pneumatic tires) and trucks such as storage areas, manufacturing units and logistics warehouses etc.
Load capacity test results for F-HD 40: For uniform load: 174kN
(Complete test report from independent laboratory available upon request.
Test reports for other sizes available upon request).